Latest Posted Projects in Pemko

Best Brothers Group of Companies - Automatic doors specialist > Pemko

Keyword:
Project Budget:
Ending In:

Pemko Q108_ Locking Astragal

Ratings

Fire Rated - UL10C - Positive PressureFire Rated – UL10C – Positive Pressure

Underwriters Laboratory 4L10Underwriters Laboratory 4L10

Finishes

BL - BlackQ108BL: BL – Black Foam

W - WhiteQ108W: W – White Foam

Posted on: 6th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S44_ Adhesive-Backed Fire/Smoke Gasketing

SiliconSeal

  • Designed for tighter frames.
  • Demonstrates extremely low closing force.
  • Seal begins compressing at 5/16″. Compresses to seal up to a 1/16″ gap.
  • S44 is available in 17, 18, 20, 21, 25 and 510 ft. coils.
  • SiliconSeal is extruded from high-temperature silicone; effective between -58°F and 450°F.
  • Self-extinguishing and non-toxic. Unaffected by sunlight, ozone and ultraviolet rays.
  • Impervious to fungus and mildew; will not deteriorate under normal exposure.
  • Meets FAR 25.853 Airworthiness Standards for Compartment Interiors.
  • Smoke tested in accordance with UBC 7-2 and UL 1784-01; meets the requirements of NFPA 105 “Standard for the Installation of Smoke Door Assemblies and Other Opening Protectives”.
  • S44, S77 and S88 are air infiltration tested in accordance with ASTM E-283-04. Air infiltration is only .09 CFM / ft of crack.
  • Category H – Gasketing – Smoke and draft control for positive pressure openings. Recommended products are PK33, PK55, S44, S88 and S773.
  • Category H gaskets for use with listed steel frames and/or classified steel covered composite, hollow metal doors rated up to and including 3 hours; wood and plastic covered composite doors rated up to and including 1-1/2 hours; and wood core doors rated for 20 minutes without hose stream. When applied to the door and frame assembly in accordance with the manufacturers installation instruction, the assembly will comply with UBC 7-2 (1997) part II.
  • Category J – Doors – gasketing that has been tested on a positive pressure fire door and frame but is not required for the door to obtain its fire door rating. Category J gasketing does not negatively affect the rating on a positive pressure door.
  • Category J gaskets for use with listed steel frames and/or classified steel covered composite, hollow metal doors rated up to and including 3 hours; wood and plastic covered composite doors rated up to and including 1-1/2 hours; and wood core doors rated for 20 minutes.

Posted on: 6th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S442 Adhesive-Backed Fire/Smoke Gasketing

Adhesive Smoke Seal, Corner Application

  • High temperature silicone
  • Self-extinguishing and non toxic
  • Long-lasting commercial grade door seal
  • Seals against smoke, fire, air, sound, and weather
  • Unaffected by sunlight, ozone, and ultraviolet rays
  • Impervious to fungus and mildew
  • Category J gaskets for use with listed steel frames and/or classified steel covered composite, hollow metal doors rated up to and including 3 hours; wood and plastic covered composite doors rated up to and including 1 1/2 hours; and wood core doors rated for 20 minutes
  • Category H gaskets for use with listed steel frames and/or classified steel covered composite, hollow metal doors rated up to and including 3 hours; wood and plastic covered composite doors rated up to and including 1 1/2 hours; and wood core doors rated for 20 minutes without hose stream

Posted on: 6th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S77_ Adhesive-Backed Fire/Smoke Gasketing

SiliconSeal

  • Designed for hollow metal and wood meeting stile applications.
  • Seal begins compressing at 5/16″. Compresses to seal up to a 1/16″ gap.
  • S77 is available in 17, 18, 20, 21 and 25 ft. coils.
  • SiliconSeal is extruded from high-temperature silicone; effective between -58°F and 450°F.
  • Self-extinguishing and non-toxic. Unaffected by sunlight, ozone and ultraviolet rays.
  • Impervious to fungus and mildew; will not deteriorate under normal exposure.
  • Meets FAR 25.853 Airworthiness Standards for Compartment Interiors.
  • Smoke tested in accordance with UBC 7-2 and UL 1784-01; meets the requirements of NFPA 105 “Standard for the Installation of Smoke Door Assemblies and Other Opening Protectives”.
  • S44, S77 and S88 are air infiltration tested in accordance with ASTM E-283-04. Air infiltration is only .09 CFM / ft of crack.
  • Category H – Gasketing – Smoke and draft control for positive pressure openings. Recommended products are PK33, PK55, S44, S88 and S773.
  • Category H gaskets for use with listed steel frames and/or classified steel covered composite, hollow metal doors rated up to and including 3 hours; wood and plastic covered composite doors rated up to and including 1-1/2 hours; and wood core doors rated for 20 minutes without hose stream. When applied to the door and frame assembly in accordance with the manufacturers installation instruction, the assembly will comply with UBC 7-2 (1997) part II.
  • Category J – Doors – gasketing that has been tested on a positive pressure fire door and frame but is not required for the door to obtain its fire door rating. Category J gasketing does not negatively affect the rating on a positive pressure door.
  • Category J gaskets for use with listed steel frames and/or classified steel covered composite, hollow metal doors rated up to and including 3 hours; wood and plastic covered composite doors rated up to and including 1-1/2 hours; and wood core doors rated for 20 minutes.

Posted on: 6th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S771_ Adhesive-Backed Fire/Smoke Gasketing

Ratings

Air Infiltration TestedAir Infiltration Tested

Intertek Testing (Warnock Hersey)Intertek Testing (Warnock Hersey)

Sound Tested - ASTM E90Sound Tested – ASTM E90

BHMA CertifiedBHMA Certified

Smoke Tested - UL1784Smoke Tested – UL1784

Fire Rated - UL10C - Positive PressureFire Rated – UL10C – Positive Pressure

Underwriters Laboratory 4L10Underwriters Laboratory 4L10

GREENGUARD Gold CertifiedGREENGUARD Gold Certified

Posted on: 6th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S771_ Self-Adhesive Astragal

Ratings
Air Infiltration Tested Air Infiltration Tested
Intertek Testing (Warnock Hersey) Intertek Testing (Warnock Hersey)
Sound Tested – ASTM E90 Sound Tested – ASTM E90
BHMA Certified BHMA Certified
Smoke Tested – UL1784 Smoke Tested – UL1784
Fire Rated – UL10C – Positive Pressure Fire Rated – UL10C – Positive Pressure
Underwriters Laboratory 4L10 Underwriters Laboratory 4L10
GREENGUARD Gold Certified GREENGUARD Gold Certified

Posted on: 7th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S772_ Adhesive-Backed Fire/Smoke Gasketing

Ratings

Air Infiltration TestedAir Infiltration Tested

Intertek Testing (Warnock Hersey)Intertek Testing (Warnock Hersey)

Sound Tested - ASTM E90Sound Tested – ASTM E90

BHMA CertifiedBHMA Certified

Smoke Tested - UL1784Smoke Tested – UL1784

Fire Rated - UL10C - Positive PressureFire Rated – UL10C – Positive Pressure

Underwriters Laboratory 4L10Underwriters Laboratory 4L10

GREENGUARD Gold CertifiedGREENGUARD Gold Certified

Posted on: 6th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S772_ Self-Adhesive Astragal

Ratings

Air Infiltration TestedAir Infiltration Tested

Intertek Testing (Warnock Hersey)Intertek Testing (Warnock Hersey)

Sound Tested - ASTM E90Sound Tested – ASTM E90

BHMA CertifiedBHMA Certified

Smoke Tested - UL1784Smoke Tested – UL1784

Fire Rated - UL10C - Positive PressureFire Rated – UL10C – Positive Pressure

Underwriters Laboratory 4L10Underwriters Laboratory 4L10

GREENGUARD Gold CertifiedGREENGUARD Gold Certified

Posted on: 7th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S773_ Adhesive-Backed Fire/Smoke Gasketing

Ratings

Air Infiltration TestedAir Infiltration Tested

Intertek Testing (Warnock Hersey)Intertek Testing (Warnock Hersey)

Sound Tested - ASTM E90Sound Tested – ASTM E90

BHMA CertifiedBHMA Certified

Smoke Tested - UL1784Smoke Tested – UL1784

Fire Rated - UL10C - Positive PressureFire Rated – UL10C – Positive Pressure

Underwriters Laboratory 4L10Underwriters Laboratory 4L10

GREENGUARD Gold CertifiedGREENGUARD Gold Certified

Posted on: 6th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project

Pemko S88_ Adhesive-Backed Fire/Smoke Gasketing

SiliconSeal

  • Seal begins compressing at 1/4″. Compresses to seal up to a 1/16″ gap.
  • Available in black, clear, dark brown, gray, tan and white.
  • S88 is available in 17, 18, 20, 21, 25, 30, 204 and 510 ft. coils.
  • SiliconSeal is extruded from high-temperature silicone; effective between -58°F and 450°F.
  • Self-extinguishing and non-toxic. Unaffected by sunlight, ozone and ultraviolet rays.
  • Impervious to fungus and mildew; will not deteriorate under normal exposure.
  • Meets FAR 25.853 Airworthiness Standards for Compartment Interiors.
  • Smoke tested in accordance with UBC 7-2 and UL 1784-01; meets the requirements of NFPA 105 “Standard for the Installation of Smoke Door Assemblies and Other Opening Protectives”.
  • S44, S77 and S88 are air infiltration tested in accordance with ASTM E-283-04. Air infiltration is only .09 CFM / ft of crack.
  • Category B – Doors – additional edge sealing system required – see Category G. Requires Category G system with gasket for fire and possibly smoke.
  • Category G – Edge-Sealing Systems – systems that are surface applied to frames or doors and required for Category B doors.
  • Category H – Gasketing – Smoke and draft control for positive pressure openings. Recommended products are PK33, PK55, S44, S88 and S773.
  • Category H gaskets for use with listed steel frames and/or classified steel covered composite, hollow metal doors rated up to and including 3 hours; wood and plastic covered composite doors rated up to and including 1-1/2 hours; and wood core doors rated for 20 minutes without hose stream. When applied to the door and frame assembly in accordance with the manufacturers installation instruction, the assembly will comply with UBC 7-2 (1997) part II.
  • Category J – Doors – gasketing that has been tested on a positive pressure fire door and frame but is not required for the door to obtain its fire door rating. Category J gasketing does not negatively affect the rating on a positive pressure door.
  • Category J gaskets for use with listed steel frames and/or classified steel covered composite, hollow metal doors rated up to and including 3 hours; wood and plastic covered composite doors rated up to and including 1-1/2 hours; and wood core doors rated for 20 minutes.
  • Category G
  • Storage and shelf life: All adhesive gaskets have a limited shelf life. This product must be used within 6 months of purchase and must be stored between 50 degrees (F) and 100 degrees (F). For further notes/details, please see Adhesive Gasketing section.

Posted on: 6th Jul 2017 Expired left Verified User

($ - $)

0 proposals

View Project